Рис. ABBПараллельные тексты EN-RU
Auxiliary contacts for external signalling
The auxiliary contacts, housed and fixed in the slot on the right-hand side of the circuit-breaker, carry out electrical signalling of the operating state of the circuit-breaker: - open/closed: indicates the position of the circuit-breaker contacts - release trip:signals circuit-breaker opening due to overcurrent release trip (for overload or shortcircuit),trip of the residual current release, of the opening coil or of the undervoltage release, or due to operation of the test pushbutton.
[ABB]
Блок-контакт для внешней сигнализации
Блок-контакт устанавливается в гнездо, расположенное в правой части автоматического выключателя. Блок-контакт служит для сигнализации положения контактов и состояния срабатывания автоматического выключателя:
- сигнализация коммутационного положения автоматического выключателя (главные контакты разомкнуты или замкнуты);
-
сигнализация срабатывания автоматического выключателя вследствие:
-
срабатывания максимального расцепителя тока (при перегрузке или коротком замыкании);
-
срабатывания расцепителя тока утечки;
-
срабатывания независимого расцепителя или минимального расцепителя напряжения;
-
нажатия кнопки тестирования автоматического выключателя.
-
срабатывания максимального расцепителя тока (при перегрузке или коротком замыкании);
Тематики
EN
Русско-английский словарь нормативно-технической терминологии > гнездо (в автоматическом выключателе)
5 прерыватель
1. contact maker2. circuit breaker3. interrupter6 прерыватель
Русско-английский новый политехнический словарь > прерыватель
7 отключение выключателя
отключение выключателя
—
[В.А.Семенов. Англо-русский словарь по релейной защите]
отключение выключателя
-
[Интент]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > отключение выключателя
8 резистор, вводимый при отключении линейного выключателя
резистор, вводимый при отключении линейного выключателя
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Русско-английский словарь нормативно-технической терминологии > резистор, вводимый при отключении линейного выключателя
9 размыкание
1. breaking2. opening10 срабатывание реле на размыкание контактов
Авиация и космонавтика. Русско-английский словарь > срабатывание реле на размыкание контактов
11 размыкание
1. opening2. breaking3. disconnectionРусско-английский словарь по информационным технологиям > размыкание
12 размыкание контактов прерывателя
Automobile industry: breaker openingУниверсальный русско-английский словарь > размыкание контактов прерывателя
13 размыкание контактов разъединителя
Engineering: breaker openingУниверсальный русско-английский словарь > размыкание контактов разъединителя
14 резистор, вводимый при отключении линейного выключателя
Engineering: circuit-breaker opening resistorУниверсальный русско-английский словарь > резистор, вводимый при отключении линейного выключателя
15 собственное время отключения
собственное время отключения
Собственным временем отключения называется интервал времени от момента подачи команды на отключение до момента прекращения соприкосновения (размыкания) дугогасительных контактов (для выключателей с шунтирующими резисторами следует различать время до момента прекращения соприкос-
новения основных дугогасительных контактов и то же – для дугогасительных контактов шунтирующей цепи).
Нормированное собственное время отключения выключателя принимается равным измеренному при отсутствии токовой нагрузки в главной цепи выключателя и при номинальном напряжении питания цепи управления.
Собственное время отключения заключает в себе время оперирования любого вспомогательного оборудования, необходимого для отключения выключателя и являющегося его неотъемлемой частью.
[IX Симпозиум «ЭЛЕКТРОТЕХНИКА 2030», доклад 4.53. 29 – 31 мая 2007 года]
собственное время отключения
to.c
Интервал времени от момента подачи команды на отключение до момента прекращения соприкосновения (размыкания) дугогасительных контактов (для выключателей с шунтирующими резисторами следует различать время до момента прекращения соприкосновения основных дугогасительных контактов и то же - для дугогасительных контактов шунтирующей цепи).
Собственное время отключения выключателя определяется в соответствии со способом отключения, как установлено ниже, и с любым устройством выдержки времени, являющимся неотъемлемой частью выключателя, установленным на свою минимальную регулировку:
а) для выключателей, отключающих с помощью любой формы вспомогательной энергии, собственное время отключения представляет интервал времени между моментом подачи команды на катушку отключения или расцепитель выключателя, находящегося во включенном положении, и моментом, когда дугогасительные контакты разомкнутся во всех полюсах;
б) для самоотключающегося выключателя собственное время отключения представляет интервал времени между моментом, при котором ток в главной цепи выключателя, находящегося во включенном положении, достигает значения срабатывания расцепителя максимального тока, и моментом, когда дугогасительные контакты разомкнутся во всех полюсах.
Нормированное собственное время отключения выключателя принимается равным измеренному при отсутствии токовой нагрузки в главной цепи выключателя и при номинальном напряжении питания цепи управления.
Для воздушных выключателей и для выключателей других видов с пневматическими приводами это время принимается равным измеренному при номинальном давлении воздуха.
Примечания
1 Собственное время отключения может изменяться в зависимости от значения отключаемого тока.
2 Для многоразрывных выключателей момент, когда дугогасительные контакты разомкнутся во всех полюсах, определяется как момент размыкания контактов первого (по времени) разрыва полюса, размыкающегося последним.
3 Собственное время отключения содержит в себе время оперирования любого вспомогательного оборудования, необходимого для отключения выключателя и являющегося его неотъемлемой частью.
[ ГОСТ Р 52565-2006]EN
opening time (of a mechanical switching device)
the interval of time between the specified instant of initiation of the opening operation and the instant when the arcing contacts have separated in all poles
NOTE – The instant of initiation of the opening operation, i.e. the application of the opening command (e.g. energizing the release, etc.) is given in the relevant specifications.
[IEV number 441-17-36]FR
durée d'ouverture (d'un appareil mécanique de connexion)
intervalle de temps entre l'instant spécifié de début de la manoeuvre d'ouverture et l'instant de la séparation des contacts d'arc sur tous les pôles
NOTE – L'instant de début de la manoeuvre d'ouverture, c'est-à-dire l'émission de l'ordre d'ouverture (par exemple l'alimentation d'un déclencheur, etc.) est donné dans les spécifications particulières.
[IEV number 441-17-36]См. также полное время отключения
Параллельные тексты EN-RU 1
Breaker closed - apply auxillary power to activate the release.
Выключатель во включенном положении. Начинает прикладываться внешнее усилие, направленное на отключение.
2
Contact separation - start of arc.
Наличие зазора между разомкнутыми контактами. Возникновение дуги.
3
Extinction of arc.
Погасание дуги.
4
Breacer open - initiation of closing movement.
Выключатель в отключенном положении. Инициирование включения.
5
Current starts to flow in the conducting path (preignition)
Начало протекания тока (начало горения дуги в изоляционном промежутке между разомкнутыми контактами).
6
Contact touch.
Соприкосновение контактов.
-
Opening time.
Собственное время отключения.
-
Arcing time
Время дуги.
-
Make time.
Время включения.
-
Break time/Interrupting time
-
Dead time.
Бестоковая пауза.
-
Closing time.
Собственное время включения.
-
Reclosing time.
Цикл автоматического повторного включения.
[Siemens]
[Перевод Интент]
Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
- выключатель, переключатель
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > собственное время отключения
16 отключение автоматического выключателя
Русско-английский словарь нормативно-технической терминологии > отключение автоматического выключателя
17 автоматический выключатель с блокировкой, препятствующей замыканию
- circuit-breaker with lock-out preventing closing
- circuit-breaker with lock-out device preventing closing
- circuit breaker with lock-out preventing closing
- circuit breaker with lock-out device preventing closing
автоматический выключатель с блокировкой, препятствующей замыканию
Выключатель, каждый подвижный контакт которого защищен от замыкания, достаточного для прохождения тока, если команда на включение подается в то время, как сохраняются определенные условия.
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]EN
circuit-breaker with lock-out preventing closing
a circuit-breaker in which none of the moving contacts can make current if the closing command is initiated while the conditions which should cause the opening operation remain established.
[IEC 62271-100, ed. 2.0 (2008-04)]
circuit-breaker with lock-out device preventing closing
a circuit-breaker in which each of the moving contacts is prevented from closing sufficiently to be capable of passing current if the closing command is initiated while specified conditions remain established.
[IEC 60947-2, ed. 4.0 (2006-05)]
circuit-breaker with lock-out preventing closing
a circuit-breaker in which none of the moving contacts can make current if the closing command is initiated while the conditions which should cause the opening operation remain established
[IEV number 441-14-23]FR
disjoncteur à fermeture empêchée
disjoncteur dont aucun des contacts mobiles ne peut établir le courant si l’ordre de fermeture est donné alors que demeurent maintenues les conditions qui devraient provoquer la manceuvre d’ouverture.
[IEC 62271-100, ed. 2.0 (2008-04)]
disjoncteur à fermeture empêchée
disjoncteur dont chacun des contacts mobiles est empêché de se fermer suffisamment pour être capable de laisser passer le courant si l’ordre de fermeture est donné alors que demeurent maintenues des conditions spécifiées.
[IEC 60947-2, ed. 4.0 (2006-05)]
disjoncteur à fermeture empêchée
disjoncteur dont aucun des contacts mobiles ne peut établir le courant si l'ordre de fermeture est donné alors que demeurent maintenues les conditions qui devraient provoquer la manoeuvre d'ouverture
[IEV number 441-14-23]Тематики
Классификация
>>>Обобщающие термины
EN
- circuit breaker with lock-out device preventing closing
- circuit breaker with lock-out preventing closing
- circuit-breaker with lock-out device preventing closing
- circuit-breaker with lock-out preventing closing
DE
FR
Русско-английский словарь нормативно-технической терминологии > автоматический выключатель с блокировкой, препятствующей замыканию
18 выключатель газовый
выключатель газовый
Выключатель, в котором дуга образуется в потоке газа, кроме воздуха.
[ ГОСТ Р 52565-2006]EN
gas-blast circuit-breaker
a circuit-breaker in which the arc develops in a blast of gas
NOTE – Where the gas is moved by a difference in pressure established by mechanical means during the opening operation of the circuit-breaker, it is termed a single pressure gas-blast circuit-breaker. Where the gas is moved by a difference in pressure established before the opening operation of the circuit-breaker, it is termed a double pressure gas-blast circuit-breaker.
[IEV number 441-14-30]FR
disjoncteur à gaz comprimé
disjoncteur dans lequel l'arc se développe dans un courant de gaz
NOTE – Lorsque le gaz est déplacé grâce à une différence de pression provoquée mécaniquement au cours de la manoeuvre d'ouverture du disjoncteur, celui-ci est appelé disjoncteur à gaz comprimé à simple pression. Lorsque le gaz est déplacé grâce à une différence de pression provoquée avant la manoeuvre d'ouverture du disjoncteur, celui-ci est appelé disjoncteur à gaz comprimé à double pression.
[IEV number 441-14-30]Тематики
- выключатель, переключатель
- высоковольтный аппарат, оборудование...
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > выключатель газовый
19 НКУ с устройствами ограничения воздействия внутренней дуги
НКУ с устройствами ограничения воздействия внутренней дуги
-
[Интент]Параллельные тексты EN-RU
Assemblies equipped with devices limiting internal arc effects (active protection)
A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.
The approaches in that direction can be of two different types:
• limiting the destructive effects of the arc, once it has occured, by means of arc detectors
• limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.
The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.
Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.
The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.
The arcing control system detects the event and sends a tripping signal to the circuit-breaker.
All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.
Figure 1 shows the possible positions where this device can be installed inside a switchboard.
The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.
In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.
Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.
The second possibility consists in installing overpressure sensors inside the switchboard.
As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.
As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.
The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.
Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.
Obviously it is essential that the device is set at fixed trip thresholds.
When an established internal overpressure is reached, the arc detector intervenes.
However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.
[ABB]НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)
Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.
Существует два типа решения проблемы в этом направлении:
• ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
• ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.
В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.
При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.
Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.
Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.
Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.
На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.
Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.
Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.
Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.
Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.
Второе решение заключается в установке внутри НКУ датчика избыточного давления.
Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.
Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.
Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.
Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.
Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.
Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.
Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Русско-английский словарь нормативно-технической терминологии > НКУ с устройствами ограничения воздействия внутренней дуги
20 автоматический выключатель
- cutout
- circuit-breaker
- circuit breaker
- CB
- breaker
- automatic switch
- automatic cutout
- automatic circuit breaker
- auto-cutout
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
3.3.4 автоматический выключатель (circuit-breaker): Контактный коммутационный аппарат, способный включать, проводить и отключать токи при нормальных условиях в цепи, а также включать, проводить в течение установленного времени и отключать (автоматически) при указанных аномальных условиях в цепи, таких, как короткое замыкание.
[МЭС 441-14-20] [1]
Источник: ГОСТ Р 51327.1-2010: Выключатели автоматические, управляемые дифференциальным током, бытового и аналогичного назначения со встроенной защитой от сверхтоков. Часть 1. Общие требования и методы испытаний оригинал документа
3.2.5 автоматический выключатель (circuit-breaker): Контактный коммутационный аппарат, способный включать, проводить и отключать токи при нормальных условиях в цепи, а также включать, проводить в течение установленного нормированного времени и отключать токи при указанных ненормальных условиях в цепи, таких как короткое замыкание.
[МЭК 60050(441-14-20)]
Источник: ГОСТ Р 51731-2010: Контакторы электромеханические бытового и аналогичного назначения оригинал документа
Русско-английский словарь нормативно-технической терминологии > автоматический выключатель
СтраницыСм. также в других словарях:
Breaker (album) — Breaker Album par Accept Sortie Mars 1981 Enregistrement Décembre 80 Janvier 81 Durée 43:56 Genre Heavy metal traditionnel Producteur Accept … Wikipédia en Français
breaker — I. noun Date: 12th century 1. a. one that breaks b. a machine or plant for breaking rocks or coal c. chiefly British one who breaks up ships or cars for salvage d. a device for opening a circuit; specifically circuit breaker 2. a wave breaking… … New Collegiate Dictionary
Coal breaker — A coal breaking plant, depicted on a postcard in 1907. A coal breaker was a coal processing plant which broke coal into various useful sizes. Coal breakers also removed impurities from the coal (typically slate) and deposited them into a culm… … Wikipedia
Circuit breaker — For other uses, see Circuit breaker (disambiguation). An air circuit breaker for low voltage (less than 1000 volts) power distribution switchgear … Wikipedia
Vacuum breaker — A vacuum breaker is an attachment commonly placed on a bibcock valve or toilet or urinal flush valve, that prevents water from being sucked backward into the public water system. This prevents contamination should the public water system s… … Wikipedia
Jaw breaker — Jaw Jaw (j[add]), n. [A modification of chaw, formed under the influence of F. joue the cheek. See {Chaw}, {Chew}.] [1913 Webster] 1. (Anat.) (a) One of the bones, usually bearing teeth, which form the framework of the mouth. (b) Hence, also, the … The Collaborative International Dictionary of English
circuit breaker — noun An electrical switch capable of opening and closing an electrical circuit in all operating conditions, including fault situations … Wiktionary
contact breaker gap — The distance between the contact points at their furthest opening … Dictionary of automotive terms
гнездо (в автоматическом выключателе) — (для размещения электрических принадлежностей, например, расцепителя)[Интент] Рис. ABB Параллельные тексты EN RU Auxiliary contacts for external signalling The auxiliary contacts, housed and fixed in the slot on the right hand side of the circuit … Справочник технического переводчика
Distributor — This article is about the engine component. For other uses, see Distributor (disambiguation). Typical distributor with distributor cap Also visible are mounting/drive shaft (bottom), vacuum advance unit (right) and capacitor (centre) A… … Wikipedia
отключение выключателя — — [В.А.Семенов. Англо русский словарь по релейной защите] отключение выключателя [Интент] Тематики релейная защита EN CB trippingcircuit breaker openingswitching to Open positionswitching to open position … Справочник технического переводчика
Перевод: с русского на английский
с английского на русский- С английского на:
- Русский
- С русского на:
- Все языки
- Английский
- Немецкий
- Французский